# Datex Ohmeda E-CO, E-CaiO, E-CaiOv - Gas Module - Double Wide (E-CO, E-CaiO, E-CaiOv)

> Source: https://shop.ezmedsource.com/products/datex-ohmeda-e-co-e-caio-e-caiov-gas-module-double-wide-e-co-e-caio-e-caiov

## At a glance

- **Manufacturer:** Datex Ohmeda
- **Model:** E-CO, E-CaiO, E-CaiOv - Gas Module - Double Wide
- **Model number:** E-CO, E-CaiO, E-CaiOv
- **Category:** Patient Monitor

## Description

The GE E-CAIO series is a double-wide gas analysis module for use with GE patient monitors equipped with compatible module racks (external or internal). The module measures oxygen (O2), nitrous oxide (N2O), and carbon dioxide (CO2); the E-CaiOv variant adds spirometry capability, and the E-CaiO and E-CaiOv variants can also identify and measure anesthetic agent gases. The module samples gas at 200 ml/min via a 3-meter sample line connected to the patient circuit or breathing system. Output displays measured gas concentrations on the monitor screen.

Configuration options:
- E-CO: O2, N2O, CO2 measurement
- E-CaiO: O2, N2O, CO2, and agent gas measurement
- E-CaiOv: O2, N2O, CO2, agent gas, and spirometry

## Tech Info

- **Flow rate:** 200 ml/min +/- 20 ml/min
- **Sample line length:** 3 meters (required for flow-rate verification)
- **Calibration gas:** 755571-HEL (5% CO2, 54.5% O2, 36.0% N2O, 2% desflurane)
- **Module width:** Double-wide format for GE module rack systems

Annual preventive maintenance and checkout required. CO2 scrubber replacement required every four years (not included in standard PM kit).

## Common Problems

- Sensor failure or inoperability
- Pump failure
- Bench failure
- Pneumatic assembly occlusion causing flow rate errors
- CO2 scrubber degradation (requires replacement every four years as part of service cycle)
- Calibration drift

## Specifications

| Spec | Value |
| --- | --- |
| Flow Rate | 200 ml/min +/- 20 ml/min |
| Module Width | Double-wide |
| Calibration Gas | 755571-HEL |
| Sample Line Length | 3 meters |
| Measured Parameters | O2, N2O, CO2 (all models); agent gas (E-CaiO, E-CaiOv); spirometry (E-CaiOv) |

## Vendor offers

### Pioneer Biomedical

- **TradeIn** · Quote on request · availability: AvailableOnRequest
- **Repair** · Quote on request · availability: AvailableOnRequest
- **Rent** · Quote on request · availability: AvailableOnRequest
- **Purchase** · Quote on request · availability: InStock

### Prescott's Med

- **Repair** · Quote on request · availability: AvailableOnRequest
- **Purchase** · Quote on request · availability: InStock