# Philips M3015A - CO2 Extension Intellivue Module (M3015A)

> Source: https://shop.ezmedsource.com/products/philips-m3015a-co2-extension-intellivue-module-m3015a

## At a glance

- **Manufacturer:** Philips
- **Model:** M3015A - CO2 Extension Intellivue Module
- **Model number:** M3015A
- **Category:** Patient Monitor

## Description

The Philips M3015A is a CO2 extension module for Philips IntelliVue patient monitors (MP20 through MP90, M3, and M4 series). It measures end-tidal CO2 using low-flow sidestream capnography, drawing approximately 50 ml/min of sample gas suitable for neonates and pediatric patients. The module connects to the IntelliVue monitor via MMS (module mounting system) and displays real-time CO2 waveforms and values on the patient display. All patient connections are electrically isolated.

The M3015A is compact and portable, weighing 0.6 kg, and is designed for continuous monitoring in critical care, perioperative, emergency, and transport settings. Optional configurations are available to add invasive blood pressure and temperature measurement capability to the CO2 measurement.

- Sidestream capnography (Microstream technology)
- Low sample flow rate (suitable for neonates)
- Optional invasive blood pressure and temperature parameters
- Transport-rated, lightweight design

## Tech Info

- **Measurement Method:** Sidestream capnography
- **Sample Flow Rate:** Approximately 50 ml/min (±10 ml/min)
- **Weight:** 0.6 kg (1.3 lbs)
- **Dimensions:** 200 x 97 x 90 mm (7.8 x 3.8 x 3.5 inches)
- **Operating Temperature:** 0°C to 40°C (32°F to 104°F)
- **Operating Humidity:** 15% to 95% RH (non-condensing)
- **Altitude Range:** -500 to 3000 m (-1640 to 9842 ft)
- **Ingress Protection:** IP32 (horizontal position)
- **Compatible Monitors:** Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90, M3, M4 via MMS connector

## Common Problems

- No communication with monitor; verify module seating on the MMS connector and monitor software compatibility.
- Parameter displays as blanked or unavailable; check sample line for occlusion or disconnection.
- CO2 waveform absent or erratic; inspect patient airway adapter and sampling line for obstruction or disconnection.
- Parameter connector damaged; physical damage to the module connector interface may prevent recognition by the monitor.
- Module not recognized after power cycle; software version mismatch between module and monitor may require firmware update.

## Specifications

| Spec | Value |
| --- | --- |
| Weight | 0.6 kg |
| Dimensions | 200 x 97 x 90 mm |
| Model Number | M3015A |
| Altitude Range | -500 to 3000 m |
| Sample Flow Rate | 50 ml/min ±10 ml/min |
| Ingress Protection | IP32 |
| Measurement Method | Sidestream capnography |
| Operating Humidity | 15% to 95% RH (non-condensing) |
| Compatible Monitors | Philips IntelliVue MP20–MP90, M3, M4 |
| Operating Temperature | 0°C to 40°C |

## Vendor offers

### Pioneer Biomedical

- **TradeIn** · Quote on request · availability: AvailableOnRequest
- **Repair** · Quote on request · availability: AvailableOnRequest
- **Rent** · Quote on request · availability: AvailableOnRequest
- **Purchase** · Quote on request · availability: InStock

### Prescott's Med

- **Repair** · Quote on request · availability: AvailableOnRequest
- **Purchase** · Quote on request · availability: InStock

## Documents

- [Philips_867041 M3015A M3015B_CheckOutProcedure.pdf](https://storage.googleapis.com/ezmedsource-product-images/product-manuals/ca9ba32f80f6449e.pdf) — manual

---
Generated from https://shop.ezmedsource.com/products/philips-m3015a-co2-extension-intellivue-module-m3015a. RFQ flow on EzMedSource is the primary commerce primitive — submit a quote request to receive responses from every vendor matching your line items.