The BD Alaris PCA 8120 is a syringe-based infusion module for the Alaris PC Unit (Model 8015), designed to deliver patient-controlled analgesia (PCA) and continuous infusion therapy. The module receives drug and dose parameters from the PC Unit's central controller and LCD display, and delivers medication via barcode-identified Alaris PCA syringes. It supports three delivery modes: continuous infusion, PCA demand dosing, and clinician-administered bolus. Dose accuracy is maintained to ±5% typical. The module integrates with BD's Guardrails Suite MX drug library for dose verification and safety monitoring.

The 8120 communicates alarms through LED indicators on the module itself and alerts on the central PC Unit display, covering occlusion, empty syringe, cassette disengagement, and dose-limit conditions. Power is supplied through the PC Unit. Compatible with standard Alaris PCA syringes.

## Tech Info

- **Pump Type:** PCA infusion module
- **Compatible Controller:** BD Alaris PC Unit (Model 8015)
- **Delivery Modes:** Continuous infusion, PCA demand dosing, clinician bolus
- **Dose Accuracy:** ±5% typical
- **Drug Library:** Guardrails Suite MX integration
- **Syringe Compatibility:** Alaris PCA syringes with barcode identification
- **Display:** LED indicators on module; central LCD via PC Unit
- **Power:** Supplied through Alaris 8015 PC Unit
- **Alarms:** Occlusion, empty syringe, cassette disengagement, dose limit reached
- **Weight:** Approx. 2.1 lbs
- **Dimensions:** Approx. 6.8" H × 3.2" W × 6.2" D

## Common Problems

- Plunger force fails during delivery cycle
- Barrel clamp assembly fails to secure syringe
- Plunger position sensor malfunction or miscalibration
- Dose calibration failure affecting accuracy verification

## Specifications

| Spec | Value |
| --- | --- |
| Depth | Approx. 6.2" |
| Width | Approx. 3.2" |
| Height | Approx. 6.8" |
| Weight | Approx. 2.1 lbs |
| Pump Type | PCA infusion module |
| Dose Accuracy | ±5% typical |
| Compatible Controller | BD Alaris PC Unit (Model 8015) |

## Vendor offers

### Prescott's Med

- **Purchase** · Quote on request · availability: AvailableOnRequest
- **Repair** · Quote on request · availability: InStock

### Adepto Medical

- **TradeIn** · Quote on request · availability: AvailableOnRequest
- **Rent** · Quote on request · availability: AvailableOnRequest
- **Purchase** · Quote on request · availability: AvailableOnRequest
- **Repair** · Quote on request · availability: InStock

## Documents

- [BD Alaris PCA 8120 operator’s manual](https://storage.googleapis.com/ezmedsource-product-images/product-manuals/dc105fb19a4cbf6d.pdf) — manual

---
Generated from https://shop.ezmedsource.com/products/unknown-bd-alaris-pca-8120. RFQ flow on EzMedSource is the primary commerce primitive — submit a quote request to receive responses from every vendor matching your line items.